Sensores de Temperatura
Duct Avg. Temp Sensor, 12 FT, 10K T2
Veris12' (3.6m) probe length, 10k ohm type 2 thermistor.
Temp Sensor, Avg, 12FT, 1K Pt, 2 Point Cal Cert
Veris12' (3.6m) probe length, 1000 ohm platinum RTD, with temperature documentation at 25°C and 35°C.
Temp Sensor, Avg, 12FT, 1K Pt, 1 Point Cal Cert
Veris12' (3.6m) probe length, 1000 ohm platinum RTD, with temperature documentation at 25°C.
Temp Sensor, Avg, 12FT, 1K Pt
Veris12' (3.6m) probe length, 1000 ohm platinum RTD.
Temp Sensor, Avg, 12FT, 100R Pt
Veris12' (3.6m) probe length, 100 ohm platinum RTD.
Accessory, BracKet, 1/4", Temp Probe, Klipet, Gray
VerisKlipet Capillary Clip. Sturdy design replaces old copper "one size only" clips. One clip can be split in to two separate units: Use one as a capill...
Ver todos los detallesAccessory, Thermowell, SS, 6.0" U Measurement
VerisStainless steel thermowell, probe length 6", fits 6" immersion probe.
Accessory, Thermowell, SS, 1.75" U Measurement
VerisStainless steel thermowell, probe length 1.75", fits 2.75" immersion probe.
Accessory, SS Thermowell (Probe Length 4")
VerisStainless steel thermowell, probe length 4", fits 4.25" immersion probe.
Accessory, Converter, 10 T3 HA, 4-20mA, 0C50
VerisTransmitter converts 10K Ohm T-2 Hi-accu. Thermistor to 4-20mA output. Scaled 0 to 50°C.
Accessory, Converter, TypeH-4-20mA, deg.F, -13to15
VerisTransmitter converts 10K Type 3 Thermistor to 4-20mA output. Scaled -13 to 15 °F.
Accessory, Converter, TypeH-4-20mA, deg.F, 0to150
VerisTransmitter converts 10K Type 3 Thermistor to 4-20mA output. Scaled 0 to 150 °F.
Accessory, Converter, TypeD, 4-20mA, deg.F, 10 to 40
VerisTransmitter converts 10K T-2 thermistor to 4-20mA output. Scaled 10 to 40 °F.
Accessory, Converter, Type D, 4-20mA, 0C50
VerisTransmitter converts 10K ohm T-2 thermistor to 4-20mA output. Scaled 0 to 50 °C.
Accessory, Converter, TypeC-4-20mA, deg.F, -10to90
VerisTransmitter converts 1000 ohm platinum RTD to 4-20mA output. Scaled -10 to 90 °F.
Accessory, Converter, TypeC-4-20mA, deg.F, 0to250
VerisTransmitter converts 1000 ohm platinum RTD to 4-20mA output. Scaled 0 to 250 °F.
Accessory, Converter, TypeC-4-20mA, deg.F, 0to150
VerisTransmitter converts 1000 ohm platinum RTD to 4-20mA output. Scaled 0 to 150 °F.
Accessory, Converter, TypeC-4-20mA, deg.F, 0to100
VerisTransmitter converts 1000 ohm platinum RTD to 4-20mA output. Scaled 0 to 100 °F.
Accessory, Converter, TypeB-4-20mA, deg.F, -58to122
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled -58 to 122 °F.
Accessory, Converter, TypeB-4-20mA, deg.F, 58to122
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled 0 to 100 °F.
Accessory, Converter, TypeB-4-20mA, deg.F, 50to95
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled 50 to 95 °F.
Accessory, Converter, TypeB-4-20mA, deg.C, -50 to 50
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled -50 to 50 °C.
Accessory, Converter, TypeB-4-20mA, deg.F, 32to212
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled 32 to 212 °F.
Accessory, Converter, TypeB-4-20mA, deg.F, 32to122
VerisTransmitter converts 100 ohm platinum RTD to 4-20mA output. Scaled 32 to 122 °F.